A-101 Dry Chemical Fire Suppression System


The A-101 Fire Suppression System is an automatic or manual fire suppression system using FORAY dry chemical agent for Class A, B, and C fires. The system is designed for use on large, off-road type construction and mining equipment, underground mining equipment and specialty vehicles.

a101_lta101_group.png

a101_lta101_group.png



  • Documents
  • Features
  • Options
Document Name Document Type Action
ANSUL "Fundamentals of Fire Extinguishment" Brochure (Rev. 04) Brochure/Flyer View
ANSUL Thermal Detector Spot (Fixed Temperatures) Data/Specifications Sheet (Rev. 01) Data/Specification Sheet View
ANSUL A-101 Fire Suppression System Models 10, 20, 30 and Models 50, 125, 250 Data/Specifications Sheet (Rev. 05) Data/Specification Sheet View
УСТАНОВКИ ПОЖАРОТУШЕНИЯ А-101 МОДЕЛИ10, 20, 30 И МОДЕЛИ 50, 125, 250 Технические характеристики (A4) (Rev. 05) Data/Specification Sheet View
ANSUL Vehicle Fire Protection - An Owner's Manual for Ansul Fire Suppression/Detection Systems (Rev. 09) Owner's Guide View
Защита автомобилей от возгорания Руководство пользователя для компании Ansul Системы тушения и обнаружения пожара (A4) (Rev. 09) Owner's Guide View
ANSUL A-101 Fire Suppression Systems Product Overview Product Overview View
ANSUL A-101/LVS Twin-Agent Suppression System Product Overview Product Overview View
ANSUL Technical Bulleltin No. 50 - Hydrostatic Retest Requirements for ANSUL Portables, Wheeled Units and Pre-Engineered Vessels (Rev. 07) Technical Bulletins View
ANSUL Technical Bulletin No. 34 - Use and Refillng Of ANSUL Gas Cartridges (Rev. 01) Technical Bulletins View
ANSUL Technical Bulletin No. 49 - Mixing of Different Types of Dry Chemical Agents (Rev. 01) Technical Bulletins View
ANSUL Technical Bulletin No. 51 - Re-Use of Dry Chemical Agents Technical Bulletins View
ANSUL Technical Bulletin No. 58 - Replacement Components and Service Technical Bulletins View
ANSUL Technical Bulletin No. 61 - Dry Chemical Clean-Up Procedures Technical Bulletins View
ANSUL Dry Chemical Agents Warranty, Disclaimer and Limitation (Rev. 01) Warranty View
СУХИЕ ХИМИЧЕСКИЕ ОГНЕТУШАЩИЕ ВЕЩЕСТВА ANSUL® ГАРАНТИЯ, ОТКАЗ ОТ ОТВЕТСТВЕННОСТИ И ОГРАНИЧЕНИЕ (Rev. 01) Warranty View
ANSUL A-101, LVS, and CHECKFIRE Fire Detection/Suppression Systems Product Warranty Warranty View

Features

Additional product features:

  • FM Approved
  • Manual and/or automatic detection and actuation
  • Extreme temperature option
  • Low-profile tank option
  • Rugged construction
  • Approved for use in underground mines for either manual or automatic agent releasedetection system incorporating MSHA approved ANSUL CHECKFIRE MP-N Detection system
  • CE marked
  • Application S

 

Options

A-101 Dry Chemical Fire Suppression System design options:

Low Profile Dry Chemical System—The LT-LP-A-101 low-profile model provides protection in environments and applications where space is at a premium. It is designed especially for underground mining environments.

Large Dry Chemical System—The LT-A-101-50 tank is factory filled with 45 lb (20.4 kg) of FORAY dry chemical. The LT-A-101-125/250 tanks are factory filled with 112 lb (50.8 kg) and 225 lb (102.1 kg), respectively, of FORAY dry chemical.

Small Dry Chemical System—The A-101-10-20-30 tank assemblies, nominal 10, 20, and 30 lb size, are factory filled with 8.5 (3.9 kg), 17 lb (7.7 kg), and 25 lb (11.3 kg), respectively, of FORAY dry chemical.