INERGEN Systems - Inert Gases


The INERGEN Fire Suppression System protects enclosed areas where people may be present, fire may strike day or night, and damage from conventional agents cannot be tolerated. Upon discharge, INERGEN agent fills the room, mixing with the air to suppress fires quickly and effectively.  Safe for people, INERGEN agent is non-synthetic and made of naturally occurring gases: nitrogen, argon, and carbon dioxide. Once discharged, it returns to the atmosphere in its natural state.

INERGEN agent is free of residues and corrosive by-products that may produce further property damage.  And because it poses no ozone depleting or global warming threat,INERGEN agent will never be subject to future legislative bans.

inergen_tanks_thumb.png

inergen_tanks.png

  • Documents
  • Features
  • Options
Document Name Document Type Action
ANSUL INERGEN Clean Agent Systems Product Profile Flyer (Rev. 01) Brochure/Flyer View
ANSUL Clean Agent Total Solutions Critical Asset Protection Flyer Brochure/Flyer View
ANSUL "Fundamentals of Fire Extinguishment" Brochure (Rev. 04) Brochure/Flyer View
ANSUL "Presidential Library" Guarded by INERGEN System Application Case Study (Rev. 01) Case Study View
ANSUL "Ivy League Library" Guarded by INERGEN System Application Case Study Case Study View
ANSUL "Church Library" Guarded by INERGEN System Application Case Study Case Study View
ANSUL "Data Center" Guarded by INERGEN System Application Case Study Case Study View
ANSUL "Electric Mining Shovel" Guarded by INERGEN System Application Case Study Case Study View
INERGEN 150-Bar Fire Suppression System Data/Specifications Sheet (Rev. 11) Data/Specification Sheet View
ANSUL INERGEN 150-Bar / 200-Bar Systems Extinguishing Agent Data/Specifications Sheet (Rev. 03) Data/Specification Sheet View
Agente Extintor INERGEN Datos/Especificaciones (A4) Data/Specification Sheet View
Agent Extincteur INERGEN Données/Spécifications (A4) Data/Specification Sheet View
INERGEN 灭火剂 数据/规格 (A4) Data/Specification Sheet View
ANSUL INERGEN 200-Bar Fire Suppression System Data/Specifications Sheet (Rev. 03) Data/Specification Sheet View
INERGEN Löschmittel Daten/Spezifikationen (A4) Data/Specification Sheet View
ANSUL At-A-Glance - End User FAQs - INERGEN Clean Agent Fire Suppression System (Rev. 02) Misc View
ANSUL INERGEN Clean Agent System with AUTOPULSE 542R Control System Engineering Specifications (Rev. 05) Specifications View
ANSUL INERGEN Clean Agent System with AUTOPULSE IQ-318 Control System Engineering Specifications (Rev. 05) Specifications View
ANSUL INERGEN Clean Agent System with AUTOPULSE IQ-636X-2 Control System Engineering Specifications (Rev. 05) Specifications View
ANSUL INERGEN Clean Agent System with AUTOPULSE Control System Engineering Specifications (Rev. 05) Specifications View
ANSUL INERGEN Clean Agent Fire Suppression System with AUTOPULSE Z-10 Control System Engineering Specifications (Rev. 03) Specifications View
ANSUL At-A-Glance - Quick Specs - INERGEN Clean Agent Fire Suppression System (Rev. 02) Specifications View
ANSUL Technical Bulletin No. 58 - Replacement Components and Service Technical Bulletins View
ANSUL INERGEN Clean-Agent Fire Suppression Systems Product Warranty (Rev. 02) Warranty View
INERGEN Environmental Warranty (Rev. 03) Warranty View
INERGEN Evergreen Discharge Warranty (Rev. 03) Warranty View
White Paper No. 1006: Summary: UL Fire Test Results INERGEN Fire Extinguishing Agent (Rev. 03) White Papers View
White Paper No. 1009: Fire and Extinguishing Tests on Computer Equipment (Rev. 01) White Papers View
White Paper No. 1005: The Physiology of INERGEN Fire Extinguishing Agent (Rev. 02) White Papers View
White Paper No. 1003: INERGEN Fire Extinguishing Agent Inerting Concentration Study Factory Mutual Research Corporation (Rev. 03) White Papers View
INERGEN White Paper No. 1016: Clean Fire Extinguishing Agents - Human Safety Testing White Papers View

Features

Applications that benefit from INERGEN Fire Suppression Systems:

  • Automated tape storage libraries
  • Computer and data processing facilities
  • Cultural and historical sites
  • Hospital and major medical facilities
  • Marine/offshore/naval
  • Museums and art galleries
  • Power generation facilities
  • Telecommunication facilities

 

Options

Cylinder assembly options include the INERGEN 150 Bar and 200 Bar fire suppression systems.

INERGEN 150 Bar—The cylinder assembly is of steel construction with a red standard finish. Four sizes are available to meet specific needs. Each has a pressure seat-type valve equipped with a gauge. The valve is constructed of forged brass and is attached to the cylinder, providing a leak-tight seal. The valve also includes a safety pressure relief device that provides relief at 2900-3300 psi (200-228 bar) per CGA test method. The cylinder charging pressure is 2175 psi at 70 °F (150 bar at 21 °C).

INERGEN 200 Bar—The cylinder assembly is of steel construc­tion with a red standard finish. One size is available. Each cylinder has a pressure seat-type valve equipped with a gauge. The valve is constructed of forged brass and is attached to the cylinder providing a leak-tight seal. The valve also includes a safety pressure relief device that provides relief at 4000-4480 psi (276-309 bar) per CGA test method. The cylinder charging pressure is 2900 psi at 70 °F (200 bar at 21 °C).